Mode conversion in a capillary taper#
A changing bore changes the local mode profiles. Expressing the pulse in those profiles introduces a connection that transfers amplitude between modes, even in a linear, lossless calculation. The worked comparison shows its effect and separates taper and wall contributions. The connection is derived in the varying coherent-wall model and is also used without a wall.
The taper coupling without a wall#
The connection belongs to the moving basis, not to the wall, so a multimode capillary taper without a wall carries it too, by default. One reason this matters: a lossless capillary is often used as a simple model of a low-loss antiresonant fibre, and a small-core taper of such a fibre must be able to convert between modes. In the true-power amplitude of the local modes the equation is
the walled generator with the wall term \(H\) zero, except that \(B\) is each channel’s
own propagation constant \(\beta_n = n_{\rm eff}\,\omega/c\) — the Marcatili index of
whatever model=, alpha= and loss_scale= the modes declare, lossless or not — rather than the wall
block’s paraxial condensation of it, so that with \(C\) dropped the flow propagates
exactly what the adiabatic route propagates. The assembly is the varying wall’s: the
cumulative \(\Phi\) carries the lowest channel for every channel, the flow’s diagonal the
rest, \(\overline{i(\beta_n - \beta_1)}\) (zero for the lowest channel) with each
channel’s normalisation term, frozen per section of the operator’s own table with the
variation and \(\sqrt{w_n/w_m}\,C_{mn}\) in the explicit residual. It applies to the
contiguous \(\mathrm{HE}_{11}\) to \(\mathrm{HE}_{1N}\) set of plain capillary modes,
\(N \ge 2\), whose radius varies
(taper_coupling_block()); a pressure gradient moves no
mode shape and needs none. taper_coupling=False on
prop_capillary(),
prop_waveguide(),
from_capillary() and
from_waveguide() is the explicit opt-out
to the adiabatic route; beside a wall it is refused, because the wall carries the
connection. The coupling is refused by name, with the opt-out named in the message, on
an envelope grid (the coupled flow is tabulated on a field grid’s increasing frequency
axis), beside a second field component or the modified noise model, and for a radius
profile without an analytic slope. The input noise model is admitted: its draw is
part of the launch, one photon per channel and bin in the entrance’s
\(\mathrm{HE}_{1m}\) set, and the coupling propagates it like any field. The record’s
modal.flow.model is "taper coupling", with the flow’s certificate rows and no wall
ratios, so a coupled run is not resumed as an adiabatic one.
These comparisons illustrate the model’s accuracy and the need to converge the retained mode set:
The adiabatic limit. A slow lossless taper (30 to 29 µm over a millimetre) converts within the Dyson remainder of the first-order coupled-mode amplitude and below its integration-by-parts (Love-type) bound, and its \(\mathrm{HE}_{11}\) is the adiabatic route’s to the same remainder, phase included.
Power conservation. The lossless flow conserves \(\sum|b_m|^2\) to its step error, converging at fourth order or better.
A finite-element solution. Against an independent scalar paraxial finite-element solution of the tapered bore in mapped coordinates — a 125 to 62.5 µm taper over 1 cm and over 10 cm between 5 mm straight ends, lossless, at 800 nm, launched in \(\mathrm{HE}_{11}\) — twenty channels reproduce the energy in every channel holding more than \(10^{-3}\) of it to 0.22 % (1 cm, where 36 % of the energy leaves \(\mathrm{HE}_{11}\)) and 0.016 % (10 cm, where 0.27 % does), every weaker channel to \(5\times10^{-7}\) of the launch, and the total power to \(2\times10^{-9}\). Eight channels are too few for the 1 cm taper, and at 400 nm, where the conversion reaches further up the ladder, thirty are needed.
The backends. The native backend runs it within the flow-parity bounds, and a lossless multimode taper runs on
backend="auto".
A lossy taper at the default step bound. The coupling carries each channel’s loss
inside its block, so over one step the channels spread by the difference of their
attenuations, and the flow’s conditioning guard refuses a spread above \(10^4\) over
dz_max. With the default loss and the default dz_max of half the length this refuses
a narrow-bore multimode taper: four helium-filled channels on a 125 to 62.5 µm taper are
refused, a 250 to 125 µm one is not. The rate depends on the bore, not on the length,
and the guard reads every frequency of the grid, so the worst is usually in the
long-wavelength collar, where the highest channel’s wall loss is largest. The refusal
names the largest dz_max it admits (the bound is \(\exp(\mathrm{d}z_{\max}\,\Delta\mu)\),
so that value is exact); pass it, or pass taper_coupling=False for the adiabatic
route.